It is my opinion that significant problems have not occurred from the use of contact lap splices because swimming pools are typically constructed with #3, grade 40 reinforcing bars that are easily encased by the gunite process for satisfactory re-bar development.ĭue to the substantial additional labor and resultant cost to install non-contact lap splices, it is this firms professional opinion that contact lap splices should be permitted for reinforcing steel installed in gunite swimming pools constructed from Pool Engineering, Inc. I believe that the pre-construction tests mentioned in IBC 1908.4.3 is, in reality, the hundreds of thousands of gunite swimming pools that have been built during the last fifty years without significant problems from the use of contact lap splices. In the present study, the bond performance of noncontact lap splices was investigated. The bar splice length of noncontact lap splices is not clearly specified due to limited test results. Government agencies throughout California typically have permitted (and are continuing to permit) contact lap splices for gunite swimming pool construction. DOI: 10.14359/51734374 Date: Abstract: Current design codes specify the bar development length empirically based on contact lap splice test results. “the use of contact lap splices necessary for support of the reinforcing is permitted when approved by the building official, based on satisfactory pre-construction tests that show that adequate encasement of the bars will be achieved, and provided that the splice is oriented so that a plane through the center of the spliced bars is perpendicular to the surface of the shotcrete” Input: SI Metric Units US Customary Units. Section 1908.4.3 of the International Building Code states: This online tool lets you calculate the tension and compression development length of a deformed reinforcing bar. This article is meant to provide information supporting the use of contact lap splices since the requirement for non-contact lap splices is somewhat unusual for swimming pool construction throughout the State of California. Many building inspectors have issued correction notices regarding the use of contact lap splices instead of non- contact lap splices in shotcrete and gunite construction in accordance with Section 1908.4.3 of the 2015 International Building Code (2016 California Building Code). The Dayton Superior DBDI Splice System, consisting of the Dowel Bar and Dowel-In. It is common in swimming pool construction to lap slice reinforcing bar when a continuous bar is not feasible.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |